Customised Portable Buildings

  • Customisable Portable Unit
  • Customisable Portable Unit
  • General Purpose Portable Unit
  • Customised Portable Building
  • General Purpose Portable Unit

Customised Portable Buildings

So many configurations possible, we will build to suit your needs.
These can be joined and/or stacked up to 3 storeys.
Standard windows and door placements can be changed/added to suit requirements.

FEATURES:

6m x 2.4m x 2.6m (internal ceiling height 2.4m)
Commercial vinyl floor
3 x double glazed windows – tilt or swing open options, roll down shutters
1 x steel door
2 x fluorescent twin tube lighting
1 x outdoor light, above door

European designed and NZ assembled
Built to last, constructed of high quality materials and precision engineered
Strong and durable – crush tested and cyclone rated
Certified lifting eyes and twist locks gives the option of transporting the buildings using hi-ab or swing lift

Electrical:

Electrical wiring installed to NZ standard portable building regulations and certificated with 4-year warrant of fitness supplied

Insulation:

Insulation high quality fire retardant material.
The under floor, walls and ceiling are lined with natural fibre, rock wool.
Underfloor insulation lining is 100mm, walls, 72mm, ceiling100mm.
Building lower floor base
Built out of 4mm mild steel plate,
20mm marine plywood floor,
100mm rock wool insulation, underneath seal cover plate 0.55.
All steel work is sand blasted, galvanised and two pack paint system.

The main manufacturing building has the following approval certification, IOS 9001,14001, OHSAS 18001, DNV factory approval, Lloyds Welding Qualification, BV & ABS product certificate.
Factory test facility test for the following, Structural, Thermal test – Central control room, Water tightness, offshore drop test, ultrasonic test, MPI test.
Structure to EN ISO 15609, AS/NZS 1170.2, 1554, 2589
Electrical to NZ Standards
Decoration NCC 2013 – building Code of Australia.
Twist lock eye point loading max = 7.4 KW.
RINA approval certificate
Stacking test load 43200
Max gross weight 8000
Tare weight 2000

FACTOR TEST:

Floor Test
Stacking Test
Top Lifting Test
Roof Test
Side Test
Lifting Forklift Pocket

EXTERNAL TEST FORCE:

200kg
6750kg / Post
5000kg
150kg / m2
150kg / m2
4280kg

INTERNAL TEST LOAD:

N/A
5000kg
3030kg
N/A
N/A
3033kg

All steel fabrication is sand blasted, electro-galvanized : Zinc 10 microns, primer coating : Zinc rich 20 Microns : Top coating :Polyurethane top coat 50 microns. Total dry film.
The building structure has been engineer tested to take a top loading of 16 tonne. The structure has been put through several different crush and drop tests. The building has been wind tested. The building can withstand wind speeds of up to188km for the roof section and 166km for the wall panels. All lifting eyes and twist locks are engineer approved and come with certification which allows the building to be transported by truck and lifted by crane, swing-lift.
The building has the strength and engineering to allow the building to be stacked up to three levels.
The building can be delivered to site by using either a hiab truck or swing-lift truck.

PRICING:

Prices quoted based on your requirements